Inspections OK
89%
16 of 18 actions
Failures by type
signal noise1
sensor timeout1
Anomalies by severity
CRITICAL1
HIGH1
LOW1
Success by config here
V190% (9/10)
V288% (7/8)
Where it is
WP07 marked on the two-floor map
Color = share of inspections OK there (green ≥ 85%, yellow ≥ 70%, red below). Size = anomaly count. Dashed ring = outdoor leg (assumed).
Assets
18 of 18 actions here reference assets registered elsewhere in assets.csv. The kit's asset and action locations do not always agree.
Registered here (assets.csv)
None.
Inspected here (actions.csv)
- PANEL-218 Electrical Panel 18 registered at WP12
- HX-210 Heat Exchanger 10 registered at WP11
- HX-213 Heat Exchanger 13 registered at WP13
- PANEL-211 Electrical Panel 11 registered at WP09
- HX-219 Heat Exchanger 19 registered at WP13
- HX-216 Heat Exchanger 16 registered at WP13
- HX-202 Heat Exchanger 02 registered at WP05
- HX-204 Heat Exchanger 04 registered at WP05
- HX-217 Heat Exchanger 17 registered at WP06
- PUMP-220 Pump 20 registered at WP14
- PANEL-203 Electrical Panel 03 registered at WP05
- HX-208 Heat Exchanger 08 registered at WP03
- VALVE-207 Valve 07 registered at WP12
Every action at WP07
18 actions across all missions, in kit time order
| Mission | Kit time | Asset | Inspection | Result | Reading | Anomaly |
|---|---|---|---|---|---|---|
| M001 | 09-01 18:24 | PANEL-218 Electrical Panel 18 | thermal | OK | 72.9 C | |
| M003 | 09-02 10:19 | HX-210 Heat Exchanger 10 | navigation | OK | 97.2 pct | |
| M004 | 09-02 18:09 | HX-213 Heat Exchanger 13 | thermal | OK | 70.6 C | |
| M007 | 09-03 18:10 | PANEL-211 Electrical Panel 11 | visual | OK | 85 score | |
| M007 | 09-03 18:16 | HX-219 Heat Exchanger 19 | thermal | OK | none | |
| M008 | 09-04 02:13 | HX-216 Heat Exchanger 16 | navigation | OK | 78.9 pct | |
| M013 | 09-05 18:28 | HX-202 Heat Exchanger 02 | acoustic | OK | 81.9 dB | |
| M014 | 09-06 02:15 | HX-204 Heat Exchanger 04 | gauge reading | OK | 136.8 psi | |
| M015 | 09-06 10:23 | HX-213 Heat Exchanger 13 | acoustic | signal noise | none | HIGH abnormal vibration |
| M016 | 09-06 18:10 | HX-219 Heat Exchanger 19 | thermal | OK | 65.3 C | |
| M019 | 09-07 18:04 | HX-217 Heat Exchanger 17 | visual | OK | 82 score | |
| M020 | 09-08 02:08 | HX-204 Heat Exchanger 04 | thermal | OK | 41.4 C | CRITICAL abnormal temperature |
| M020 | 09-08 02:16 | PUMP-220 Pump 20 | navigation | OK | 91.7 pct | |
| M023 | 09-09 02:12 | PANEL-203 Electrical Panel 03 | navigation | OK | 87.7 pct | |
| M024 | 09-09 10:11 | HX-204 Heat Exchanger 04 | visual | OK | 99 score | |
| M025 | 09-09 18:16 | HX-208 Heat Exchanger 08 | gauge reading | sensor timeout | 117.7 psiquestionable | LOW gauge out of range |
| M026 | 09-10 02:09 | VALVE-207 Valve 07 | visual | OK | 90 score | |
| M027 | 09-10 10:10 | PANEL-211 Electrical Panel 11 | thermal | OK | 57.8 C |