Inspections OK
69%
11 of 16 actions
Failures by type
target not detected2
reading unreliable2
sensor timeout1
Anomalies by severity
MEDIUM2
Success by config here
V164% (7/11)
V280% (4/5)
Where it is
WP15 marked on the two-floor map
Color = share of inspections OK there (green ≥ 85%, yellow ≥ 70%, red below). Size = anomaly count. Dashed ring = outdoor leg (assumed).
Assets
16 of 16 actions here reference assets registered elsewhere in assets.csv. The kit's asset and action locations do not always agree.
Registered here (assets.csv)
None.
Inspected here (actions.csv)
- PUMP-205 Pump 05 registered at WP10
- HX-201 Heat Exchanger 01 registered at WP05
- PANEL-218 Electrical Panel 18 registered at WP12
- HX-216 Heat Exchanger 16 registered at WP13
- PUMP-220 Pump 20 registered at WP14
- HX-202 Heat Exchanger 02 registered at WP05
- HX-217 Heat Exchanger 17 registered at WP06
- PANEL-203 Electrical Panel 03 registered at WP05
- VALVE-207 Valve 07 registered at WP12
- HX-210 Heat Exchanger 10 registered at WP11
Every action at WP15
16 actions across all missions, in kit time order
| Mission | Kit time | Asset | Inspection | Result | Reading | Anomaly |
|---|---|---|---|---|---|---|
| M001 | 09-01 18:21 | PUMP-205 Pump 05 | visual | OK | none | |
| M003 | 09-02 10:22 | HX-201 Heat Exchanger 01 | thermal | target not detected | 59.1 Cquestionable | MEDIUM abnormal temperature |
| M005 | 09-03 02:17 | HX-201 Heat Exchanger 01 | acoustic | OK | 80.2 dB | |
| M008 | 09-04 02:05 | PANEL-218 Electrical Panel 18 | acoustic | OK | none | |
| M009 | 09-04 10:07 | HX-216 Heat Exchanger 16 | gauge reading | OK | 99.7 psi | |
| M010 | 09-04 18:06 | PUMP-220 Pump 20 | navigation | OK | 98.9 pct | |
| M011 | 09-05 02:33 | PANEL-218 Electrical Panel 18 | acoustic | reading unreliable | 70.9 dBquestionable | |
| M012 | 09-05 10:21 | PANEL-218 Electrical Panel 18 | thermal | sensor timeout | 63 Cquestionable | MEDIUM abnormal temperature |
| M014 | 09-06 02:23 | HX-202 Heat Exchanger 02 | visual | OK | 83 score | |
| M016 | 09-06 18:23 | HX-216 Heat Exchanger 16 | visual | target not detected | 82 scorequestionable | |
| M018 | 09-07 10:19 | HX-217 Heat Exchanger 17 | thermal | OK | 65 C | |
| M020 | 09-08 02:14 | PANEL-203 Electrical Panel 03 | acoustic | OK | 77.5 dB | |
| M021 | 09-08 10:06 | VALVE-207 Valve 07 | acoustic | reading unreliable | 52.9 dBquestionable | |
| M022 | 09-08 18:24 | PANEL-218 Electrical Panel 18 | visual | OK | 88 score | |
| M024 | 09-09 10:15 | PANEL-203 Electrical Panel 03 | thermal | OK | 57.4 C | |
| M026 | 09-10 02:23 | HX-210 Heat Exchanger 10 | acoustic | OK | 79.4 dB |